KeyboardPartner downloads

Keyswerk

Available files

12 items

Name Type Size Modified
Parent directoryGo up one level Folder — —
HX3_mk7 Folder —
CHANGELOG.md.bak BAK file 3.4 KB
HX35_Editor_Keyswerk.zip ZIP file 4.7 MB
HX35_params_5619.xlsx XLSX file 476 KB
HX35_Update_Keyswerk_5625.zip ZIP file 7.8 MB
SDCARD_5.201_single.zip ZIP file 383 KB
SDCARD_5.502_bus.zip ZIP file 362 KB
SDCARD_5.502_single.zip ZIP file 356 KB
SDCARD_5.519_bus.zip ZIP file 363 KB
SDCARD_5.622_bus.zip ZIP file 361 KB
SDCARD_5.625_bus.zip ZIP file 348 KB
SDCARD_5.631_bus.zip ZIP file 349 KB

Select a folder to browse its contents or select a file to download it.

Documentation



Dateien für Keyswerk/Böhm

Nicht für Endanwender - nur zum Test!

Test versions for Keyswerk/Böhm only - do not use!

Release history

Changelog

WICHTIG: Ernste Fehler, die ein Update unbedingt erforderlich machen, sind fett gedruckt.

20.01.2021 Firmware #5.631, EEPROM #5.631, Editor #5.630, FPGA #10012021

  • Firmware: Distortion on H100 percussion notes fixed
  • Firmware: Bugfix for organs configured with tab switches, will init start-up correctly
  • EEPROM: Reduced busbar levels (standard value 100 instead of 127)
  • EEPROM: Reduced Vibrato/Chorus dry/wet levels to prevent distortion
  • Editor/Updater: Increased reliability, will shut down drawbar, pot and button scanning during update
  • Editor/Updater: Trackbars will not send new value until mouse button is released; prevents crashes on particular PCs
  • FPGA: Better 6550 tube simulation, results in somewhat softer overdrive
  • FPGA: Higher Tube Amp Gain, lower AO28 Preamp noise

24.11.2020 Firmware #5.622, Editor #5.622, FPGA #29112020

  • Changed rotor diffusor/filter/mixing coefficients in FPGA
  • Reduced noise in AO28 amp simulation
  • Fixed small bug in Editor (crash on Load INI file)

26.10.2020 Firmware #5.621, Editor #5.621

  • Firmware: Added feature "MIDI CC Threshold" for tabs and inverted tabs to switch on or off by specific controller value
  • Editor: Added drop-down menu items "Threshold" and "Threshold inverted"
  • New CC set "#0 NI B4 D4B", can be uploaded alternatively to "#0 NI B4 d3c" (CSV file, use MIDI CC Editor)

08.10.2020 Firmware #5.620, FPGA #01102020, Scan #5x.29

  • Firmware: Bugfix, Hammond SK CCs did not respond to drawbars
  • Scan Driver: Bugfix, bug in all scan drivers prevented reception of MIDI sustain and sostenuto commands due to NI B4 CC set anomalies
  • FPGA: Bugfix, wrong phase relationship of DAC MCLK signal caused audible artefacts on Extension Board audio output
  • FPGA: Changed AO28 simulation noise behaviour to "somewhat better than new B3"
  • FPGA: New swell pedal filter arrangement for better S/N performance
  • CCSET: Deleted unnecessary entries for Hammond XK/SK MIDI (CC #66 prevented sustain pedal function)

Note: AO28 simulation adds some "coloured" noise to input and intermediate tube stages. S/N ratio is in the -78 dB range, so noise is somewhat lower than on a real B3, although noticeable. This is intended.

31.08.2020 Firmware #5.619, FPGA #310082020, Editor #5.618, Scan #5x.28

  • Firmware: Bugfix, H100 Percussion distortion when multiple harmonics activated; level reduced
  • Editor: Added separate Save/Open menus for INI files
  • Editor: Added pop-up menu (right mouse button) for main table
  • FPGA: Added highpass filter for vibrato LC line reflection
  • Scan Driver: Bugfix, PERC ON on NI B4 CC Set did not work, route-through for Sustain and Sostenuto CCs implemented
  • Updater script: New params for vibrato
  • Finalize scripts: Enable drawbar save on #1498

Note: Check for System Inits parameter #1498 bit 7 (leftmost) is set, otherwise drawbars will not be saved. Default value for #1498 is 135.

11/25/2019 Firmware #5.519, BETA

Geänderte Dateien: Firmware, EEPROM

  • FW: Bugfix B3 Percussion Volume
  • FW: Bugfix ADSR-Attack bei ADSR/EG Percussion Mode
  • FW: Bugfix Aktualisierung Busbar Offsets (#1288 ff.), Busbar Levels (#1272 ff.)
  • EEPROM: Geänderte Struktur, Parameternummern haben sich NICHT geändert
  • EEPROM: Slow/Fast Parameter für PHR waren bei einigen Einstellungen vertauscht

11/25/2019 Firmware #5.518, SCAN #XX.24, BETA

Geänderte Dateien: FPGA, Firmware, Scan-Treiber

  • SCAN: Experimenteller SysEx-Interpreter entfernt
  • SCAN: Schnellere MIDI-Empfangsroutine
  • SCAN: MIDI-Eingang 2 entfernt
  • FW: Alte PHR-Parameter umgestellt auf neues Oversampling (Delay-Parameter verdoppelt)
  • FPGA: Organ Amp auf DABD2 L und/oder R schaltbar